page 1 page 2 page 3 page 4 page 5 page 6 page 7 page 8 page 9 page 10 page 11 page 12 page 13 page 14 page 15 page 16 page 17 page 18 page 19 page 20 page 21 page 22 page 23 page 24 page 25 page 26 page 27 page 28 page 29 page 30 page 31 page 32 page 33 page 34 page 35 page 36 page 37 page 38 page 39 page 40 page 41 page 42 page 43 page 44 page 45 page 46 page 47 page 48 page 49 page 50 page 51 page 52
|
will last for up to 6000 injections. He illustrated the use of the columns with applications including the analysis of cholesterol and fluticasone as well as peptide analysis. His conclusion was that they are a convenient and cheap alternative to uHPLC. Richard Houghton presented on ' Generic approach to validation of small molecule LC-MS/ MS biomarker assays'. He described the successful use of synthetic surrogate matrix calibration procedures to overcome the presence of endogenous analyte. This was illustrated with data from a number of steroid and amino acid assays that had been validated using this approach. Martyn Hlhorst ( PRA International) presented on ' Quantitative Determination of steroids using LC- MS/ MS. He describes the theory behind Atmospheric Pressure Photoionisation ( APPI) and illustrated the potential for sensitivity gains over more conventional APCI of ESI ionization techniques for the analysis of steroid molecules. Session 4 - Dried Blood Spot Analysis ( Chaired by Ian Wilson) This 90 minute session featured a series of talks from Matthew Barfield ( GSK), Tony Edge ( AZ), Graeme Clark ( Pfizer), Lee Goodwin ( Covance) and Shirish Yakkundi ( Queens University, Belfast) discussing the experiences of each of these organisations with the technique of dried blood spot analysis ( DBA). GSK have pioneered the technique and have the most experience in this area. They have validated over 60 bioanalytical assays using this technique of which two compounds are now in Phase 1 clinical development. The advantage of using DBA is that it only requires very small volumes of blood allowing serial bleeds from preclinical species such as mice. This leads to much better preclinical pharmaco and toxicokinetic data. The logistics of collecting DBA samples is much simpler in the animal facility or clinic with blood being spotted onto special filter paper card and then allowed to dry for 2 hour. Samples are then stored at room temperature in plastic bags containing a desiccant. Under these conditions, samples have been shown to be stable for some considerable time. Samples can be posted in the mail, avoiding the conventional difficulties of shipping frozen plasma packed on dry ice. With demonstration of good stability of labile metabolites, good reproducibility of sampling across blood spot ( avoiding the " halo"), simple solvent extraction methodologies and comparative ( and in some cases superior data) to plasma, the technique is fast becoming established in discovery and preclinical arenas of large pharma companies. With some challenges still to overcome, such as method sensitivity, this is a technique that looks like it is here to stay. Session 5 - Incurred Sample Reproducibility ( Chaired by Derek Stevenson) This final short session of the day featured a single presentation from Frank Mullins ( Icon Development Solutions) on ' Case Studies in Incurred Sample Reanalysis - Problems Encountered'. How to measure Incurred Sample Reanalysis has been a hot topic of discussion around the industry over the last couple of years. However, this is only part of the challenge of ISR facing the bioanalyst. As the industry comes to some consensus about measurement, the bigger issue now is how to investigate cases of failed ISR. The presentation centred around two case studies describing the investigation process. The conclusions were that validation of assays in blank control matrix don't highlight issues involving labile metabolites. Pooled incurred samples are required to support freeze/ thaw and long- term stability data. Constant vigilance is required by bioanalytical laboratories and speedy communication of sample instability must be communicated effectively to sample collection facilities. Session 6 - Comparing Immunoassay Technologies ( Chaired by Ray Briggs) Wednesday's first session was delivered by John Allinson ( Veeda) ( FIBMS) who gave a comprehensive overview of emerging immunoassay technology platforms. John compared open immunoassay systems including Luminex, Mesoscale Discovery ( MSD), Grifols Triturus and the Gyros Gyrolab, with closed system clinical analysers for immunoassays used in diagnostic labs such as the DPC Immulite. John asked the question ' Why Multiplex?' and presented the various advantages of using a multiplex approach including reduced cost, time and sample volume. However validation of a multiplex assay can be complex and failure of one analyte to meet acceptance criteria can lead to many repeats. A more elegant approach which has all the advantages of multiplexing without the pitfalls of multiplexing is the single assay platform the Gyros Gyrolab. John presented interesting work which has been carried out on this platform on three biomarkers of Alzheimer's disease Abeta amyloid 1- 40, Abeta amyloid 1- 42 and total Abeta in CSF and plasma illustrating the benefits of the Gyrolab compared with DELFIA or Luminex. Session 7 - Unwanted immunogenicity ( Chaired by Ian Wilson) Geoff Hale ( BioAnaLab) kicked off the session presenting some of the challenges of anti-drug antibody ( ADA) testing for the bioanalyst. With the rise in the number of biopharmaceuticals such as monoclonal antibodies in the drug development pipeline, ADA testing is becoming an increasingly important part of the regulatory package. An immune response to the drug is part of the body's natural defence's, gaining an understanding of this response is key to the success of the drug. Some biopharmaceuticals may be non immunogenic, an ideal situation, however where antibodies are evoked they can fall into a number of categories. Some ADA will have no effect, again a good result for the pharma company, however others may affect PK/ PD by neutralising the biological effects decreasing efficacy, while others may lead to serious adverse events such as a reaction with a native protein. Recent white papers and EMEA guidelines were covered in this talk are leading to a common understanding of the validation parameters for these quasi- quantitative assays. From Geoff's presentation it is clear challenges still remain in the availability of appropriate positive controls, establishment of assay cut points, requirement for sensitivity and establishing the clinical relevance of the assay data, with many of these factors having to be assessed case- by case. Figure 4. The MesoScale Discovery and the Gyros Gyrolab Immunoassay platforms 45 46November/ December 2009 Christopher Kirton ( Huntington Life Sciences) followed with a talk entitled In vitro cytokine release' posing the key question is this novel antibody therapeutic going to induce cytokine release syndrome ( CRS)? This has been seen with antibodies such as Rituximab and more recently TGN1412, leading to release of TNF- ?? , IFN- ?? and IL- 6, which can lead to serious adverse events. A bead-based muliplex immunoassay using flow cytometry detection has been set up and early results were presented at this meeting showing its potential to as a tool to predict CRS risk of a novel drug in vivo. Small molecule re- analysis was picked up in the session too continuing the theme of the importance of this topic throughout the meeting with Jaap Wieling ( Xendo) talk entitled ' Accuracy of incurred samples'. To complete the session before lunch David Perrett ( Queen Mary, University of London) gave a rather gruesome demonstration of the inadequacy of sterilisation/ decomtamination procedures in use in hospitals and dentists. Current procedures do not lead to the complete removal of Prion Proteins ( PrP), the cause of new variant Creutzfeldt- Jakob disease ( CJD). Even at very low levels PrP present a risk of cross- infection. Prion proteins are highly hydrophobic and have a high affinity for stainless steel, the material used for most surgical instruments. However new reagents are being developed and patented at Queen Marys to reveal contaminant PrPs in surgical instruments which will significantly reduce risk of cross- infection. Session 8 - Regulatory approaches to evolving technologies ( Chaired by Steve Westwood) Brian Booth ( FDA) joined the meeting by teleconference and covered ( some of) what the FDA is thinking offering a personal view on current bioanalytical guidelines. Amongst the take home messages from Brian were that some issues of method validation are clear cut, while others depend on the situation. How much validation is required really does depend on the particular goal and everyone has a responsibility to ensure that the method is fit for its ultimate purpose. Brian concluded with the comment that the FDA can't ( won't) figure everything out. An impromptu discussion was held covering the 2008 EMEA Concept Paper on Bioanalytical method validation including Graeme Smith and Howard Hill ( HLS) and Ray Briggs. Overall there were mixed views about the wisdom of ' another' set of guidelines which may lead to lack of clarity about validation requirements, however some delegates felt that having EMEA guidance would push the field forward, and challenge the FDA, which would be welcomed. The final session of the day chaired by John Lough ( University of Sunderland) stayed on a large molecule theme with Jaap Weiling ( Xendo) and Matt Ewles ( Covance) presenting on immunoassays with elemental tagged antibodies and an introduction to the Quantification of proteins using proteolytic digestion by LC- MS/ MS. Session 9 - MS of Biological analytes ( Chaired by John Smeraglia) John Smeraglia ( Pfizer) chaired this session with three talks given by Eric Ezan ( CEA Institute of Biology and Technology), Chris Barton ( Quotient Bioresearch) and Hendrick Neubert ( Pfizer). The theme of this session was the application of LC-MS/ MS to proteins, and its potential to supersede traditional immunoassays. Eric lead with a side- by side comparison of ELISA vs LC- MS. The initial challenge laid down by Eric was that immunoassays are fundamentally flawed due to problems with lack of concordance of standards across platforms and questions the specificity of antibodies ( what is measured? Free, bound or total analyte?). Therefore it is essential we look for alternatives. Could mass spectrometry be the answer? Eric made a strong case for mass spectrometry as an alternative in the future particularly for biotherapeutics and in immunogenicity testing, linking in well with some of the challenges presented by Geoff Hale in earlier session. Further evidence was presented by Chris where the application of BioMS to biomarker testing has crossed species from equine testing looking at markers of drug abuse in horses, driven by the absence of suitable immunoassay methods) to the clinic where human samples are now being tested. Hendrik brought the whole story together presenting his work on the development of an assay for low abundance targets of antibody therapeutics using immunoaffinity enrichment and LCMS- MS. This work demonstrates the power of combined approaches to answer complex sophisticated questions about percentages of free and bound drugs. Session 10 - Concluding session ( Chaired by Robin Whelpton) In this final session John Stobaugh ( University of Kansas) presented work on the evolution of chemical reactions for determination of protein 3- nitro- tyrosine, followed by Gavin O' Connor ( LGC) talking about protein quantification of mass spectrometry. Conference closing comments John Lough ( President of the Chromatographic Society) closed the conference commenting that it had been a good conference from a scientific standpoint with a wide variety of topics covered. Attendance was very good taking the present economic climate into consideration. ( although down by around 20- 30% on previous years). John thanked the organising committee and major sponsors of the event ( Quotient Bioresearch Ltd, Waters and York Bioanalytical solutions). Figure 5. Slide from Brian Boothe's presentation on ' Bioanalytical Method Validation: ( some of) What the FDA is thinking'. |